ProductIntroduce£º 1. Smart design
The familiar PC system makes the system intuitive and easy to use. Flexible design allows system to be used conveniently.
2. Probes information
Configuration
|
Probes
|
5 Steps Multi-frequency
|
Image
|
Standard:
|
3.5Mhz abdominal probe
|
2.0, 3.0, 3.5, 4.0, 5.5Mhz
|
|
|
7.5Mhz linear probe
|
6.0, 6.5, 7.5, 10.0, 12.0Mhz
|
|
Options:
|
6.5Mhz transvaginal probe
|
5.0, 6.0, 6.5, 7.5, 9.0Mhz
|
|
|
3.5MHz micro-convex probe
|
2.0, 2.5, 3.5, 4.5, 5.0Mhz
|
|
|
3.5Mhz phased array probe
|
2.0, 3.0, 3.5, 4.0, 5.5Mhz
|
|
|
4D volume probe
|
2.0, 3.0, 3.5, 4.0, 5.5Mhz
|
|
3. Technical specifications:
Displaying mode
|
B,B/B,4B,B/M,M,PW,B/C,B/C/D,B/D, duplex, triplex, CFM
|
Signal processing:
|
Full-digital beam forming, dynamic filter, dynamic real time receiving focusing, RDA, spectral processing, CFM processing, real-time dynamic focusing, dynamic aperture in all fields
|
Image processing:
|
THI
PSHI TM broadband multi-frequency harmonic image
Speckle-reduction
Power adjustable
Smoothing function
iBeam TM intelligent space image technology
iZoom TM undistorted full screen image
Free Xros M
Engineer control technology with low power consumption
Edge enhancement Image optimizing disposal
One-key optimization
Image conversion
Doppler Sound output volume adjustable
Wall filter adjustable
Base line adjustable
Sampling frame adjustable
Spectrum sampling volume adjustable
Spectrum sampling volume angle adjustable
PRF adjustable
|
General measurement
|
B mode-distance, circumference, area, volume, angle, area Red, Diam Red
M mode- distance, time, velocity, heart rate
|
Abdomen
measurement
|
Liver, GB, Aorta, GBWT, CBD, Portal Vein, Spleen
|
OB packages
|
EDD table :GS ,BPD, CRL,FL,YS,TAD,LV,OFD,NT,AC,HC, APAD, Cxlength.
|
Gynecological packages
|
Uterine measurement (Uterine diameter, uterine endometrial); left/right ovary measurement; left/right sacculus measurement; Cervix; Uterine depth
|
Urology packages
|
Left/right kidney measurement, Volume, Cortex
|
Small parts Measurement
|
Left/ right thyroid, volume, Isthnus and calculating report
|
Cardiac Measurement Package
|
Heart rate, Valve speed, LV, aortic, mitral, ventricular
|
Skeletal & Muscles
|
Skeletal & Muscles, distance, area, Hip angle
|
Vascular
|
Senosis D, senosis A, Lt/Rt VVA, Lt/Rt Rulb, Lt/Rt ICA
|
Scanning depth
|
300mm
|
Body mark
|
Abdominal ,Cardiology, Gynecology, Obstetrics, Small parts
|
Cine loop
|
Automatically & manually, speed control
|
Image storage format
|
BMP, JPEG, PNG
|
Input/output ports
|
VGA, USB port, DICOM port
|
Standard Configuration
|
Main unit, 12 inch LCD monitor, 3.5Mhz convex probe, 7.5Mhz linear probe,2 probe connectors, hard disk
|
Options
|
6.5Mhz transvaginal probe, 3.5Mhz micro-convex probe, 3.5Mhz phased array probe, 4D volume probe, trolley, battery, laser printer, DICOM 3.0
|
|