ProductIntroduce£º lisa Processors is fully automated two-plate ELISA processing system capable of adding sample,incubation,washing and data processing.
It is complete solution for your IVD ELISA assays. The system combines a high precision pipetting unit with stable incubators and efficiency washers and photometer unit.
KGW1000 Modularity
1 Robotic hand.
1 Pipetting probe, 1ul stepping (1000ul volumes).
80 Sample rack, 92 Dilution rack.
2 units 96 well microplate(pipetting,incubator,reading).
1 unit independent washer&reader( two 8 nozzle manifolds).
Testing Range:
1. TORCH SERIES 4. THYROID AUTOIMMUNITY SERIES
Toxo, RV, CMV, HSV etc. T3, T4, FT3, TSH etc
2. HEPATITIS SERIES 5. ENDOCRINE SERIES
HAV, HBV, HCV, HDV, HEV etc. E2, E3, LH, FSH, HCG, Pro, PRL etc.
3. VENEREAL SERIES 6. TUMOR MARKER SERIES
HIV, TP, MP, CT etc. CEA, AFP, PSA F-PSA, CAL9-9, CAL 25, CA15-3, CA242.
Modularity Composition:
2 microplate ,80 Sample rack, 92 Dilution rack.
All-in-one microplate reader and washer
8 special reagent racks, 1 general reagent racks.
Robotic precision probes and automated washing system.
Washer:
Two 8 nozzle manifolds
Automatic liquid level sensor detection
Separate aspiration and dispense probes prevent cross contamination
Reader:
8 independent photometric channels
Wavelength range 400-700nm
2 precision filters (450,630nm), 2 more available on request.
User-friendly Software:
LIS system available (laboratory information system)
Large data storage capacity
Professional service software monitor process on line status.
|
KGW1000 |
Type |
Fully automated ELISA analyzer |
Sample racks |
60 or 80 – 12 mm sample tubes or 40 - 16 mm sample tubes |
Dilution rack |
92 positions |
Reagents holder |
modular racks to hold calibrators, controls and reagents for 8 methods on line |
Liquid reservoirs |
external tanks equipped with level sensors; 2 washing buffer |
Microtiter plates |
2 plates (96 wells) with incubation capability, from room temperature to 45 °C |
Dispensing system |
1 aspirating-dispensing probe with X-Y-Z movement; dilution system with a syringe of 1000 μl, continuous flow washing station |
Washing system |
two 8 nozzle on line manifolds with automatic adaptation for the different micro-plates height |
Washing Residual volume |
< 3μl |
Washing inaccuracy |
CV < 5 % with 300 μl |
Readingsystem |
8 independent photometric channels for mono and bichromatic reading |
Optical filters |
2 filters (450 and 630 nm); 2 more on request (max 4 filters) |
Readinginaccuracy |
± 1% from 0.000 to 1.500 OD ± 2% from 1.500 to 3.000 OD |
Dispensation |
from 8 ml to 1000 ml with 1μl resolution; inaccuracy ±1% with 100 μl |
Software |
Windows 98 and XP operating system, to set up the work list, patient reports and results filing; calibration curves storage for each carried-out test |
Connection |
LIS interface capability, work list set up from Host computer.
Capability of connecting more instruments to a single PC. |
Power Supply |
200/110 VAC, 50-60 Hz |
Dimension |
620 x 820 x 720 |
Weight |
80 Kg |
|