ProductName£º Patient Monitor KGW-9000
ProductIntroduce£º

Characteristics

l          Standard configuration with 3-lead or 7-lead ECG/HR, RESP, dual TEMP, SpO2/Pulse, NIBP; Optional parameter with 12-lead ECG/HR, dual IBP, EtCO2, Anesthetic Gas

l          12.1 High brightness color TFT LCD display

l          Unique all-lead ECG on-one-screen display, which can facilitate the diagnosis and analysis of cardiac disease

l          Bed to bed ,VGA output, parameter display with big character

l          Store & review 168 hours trend data and trend maps

l          Store & review 1800 pieces of alarm events

l          Store & review 1000 pieces of NIBP measurement data

l          Store & review 30 minutes one important lead’s EGC waveform

l          Built-in recorder (optional) supports real-time recording, trigger printout by alarm

l          Optional function of Calculator of drug concentration, Optional function of Display of oxyCRG

l          Rechargeable battery, can continue working when AC power is off

l          Resistant to high-frequency electrotome and is protected against defibrillation effects

Size and Weight

Size: 318mm×264mm×152mm

Weight: 4.5kg

Power supply

Power Voltage: AC 100-240V 50/60Hz

Power Input: ≤85VA

Display

Size: 12.1″

Type: Color TFT-LCD     

Resolution: 800×600 pixels or higher

Battery

Type: Rechargeable Lead acid cell, 12V/2.0AH

Charge time: ≤10 hours

Working time: 60min when using normally

Environment

Ambient Temperature: Working temperature: 0~+40ºC; If use EtCO2 of IRMA, working temperature: +10~+40ºC; If use O2 sensor of IRMA, working temperature: +10~+35ºC; Transportation and storage temperature: –20~+55ºC

Relative humidity: Working ≤85%, Transportation and storage ≤93%

Atmospheric pressure: Working 860~1060 hPa, Transportation and storage 500~1060 hPa

ECG

Lead Mode: 5-leads ECG input, 3-leads ECG input, 12-leads ECG input (option)

Lead selection: I, II, III, aVR, aVL, aVF, V-; I, , III; I, II, III, aVR, aVL, aVF, V1~V6 (option)

Gain: AUTO, 0.25x, 0.5x, 1.0x, 2.0x, 4.0x

Input impedance: ≥5.0 Mohm

CMRR: MON ≥105dB, OPS ≥105dB

Frequency response: 5-leads or 3-leads ECG module: MON 0.5~40Hz,OPS 1~25Hz ; 12-leads ECG module: MON 0.5~25Hz, OPS 1~15Hz

Electrode offset potential: 5-leads or 3-leads ECG module: ±500mV d.c ; 12-leads ECG module: ±300mV d.c.

Leakage Current: <10 uA

ECG signal range: 5-leads or 3-leads ECG module: ±6.0 Mv; 12-leads ECG module: ±3.0mV

Baseline recovery: <5 sec After Defibrillation. (MON or OPS mode)

Pacemaker pulses: No rejection of pulses with amplitude: ±2mV ~ ±700 mV & duration: 0.5 ~ 2.0 ms.

Insulation: Breakdown Voltage 4000VAC 50/60Hz

Indication of electrode separation: Every electrode (exclusive of RL)

Sweep speed: 12.5mm/s, 25mm/s, 50mm/s

HR

Range : 5 or 3 leads ECG module: 10~300 bpm; 12-leads ECG module: 25¡«254bpm

Refreshing time: Per 4 pulses

Resolution: 1 bpm

Accuracy: ±1% or ±1 bpm, whichever is greater

Sensitivity: ≥0.2mVpp

Alarm range: 0~300 bpm, continuously adjustable between upper limit and lower limit

Alarm indication: Sound and light alarming

Time to Alarm for Tachycardia: Average 4 seconds

Tall T-Wave Rejection Capability: 0-1 mV T-Wave amplitude

Response Time of Heart Rate: HR change from 80 to 120 bpm;    Range: 6 to 10 seconds

Meter to Change in Heart Rate: HR change from 80 to 40 bpm ;     Range: 6 to 10 seconds

RESP

Method: Impedance variation between RA-LL (R-F)

Measuring impedance range: 0.2 ~3 Ohms

Excitation frequency: 64.8 kHz

Excitation current: ≤300μA at 64.8 kHz

Base line impedance range: 500~4000 Ohms (50~120 kHz exciting frequency)

Measurement Range: 0~150 rpm

Resolution: 1 rpm

Accuracy: ±2 rpm

Gain: x1, x2, x4

Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s

Delay of Apnea Alarm: Off, 20s, 40s, 60s

Alarm indication: Sound and light indication

ST segment

Measurement range: -2.0mV~2.0mV

Accuracy: -0.8mV~0.8mV£º±0.02mV or ±10% whichever is greater, Over ±0.8mV: unspecified

Resolution: 0.01mV

Refreshing time: 10s

TEMP

Measurement Range: 25.0~50.0ºC

Accuracy: ±0.1ºC

Resolution: 0.1ºC

Unit: Celsius (ºC), Fahrenheit (ºF)

Refreshing time: 1s

Self check: Every 10 minutes

Accuracy: At 45.1ºC~50.0ºC, ±0.2ºC (include of probe); At 25.0ºC~50.0ºC, ±0.1ºC (exclusive of probe)

Connecting cable: Compatible with YSI-400

Range of alarm: 25.0~50.0ºC, continuously adjustable between upper limit and lower limit

Alarm indication: Sound and light alarming

SpO2

Measurement Range: 0~100%

Resolution: 1%

Accuracy: At 70~100%, ±2%, At 0~69%, unspecified

Data update period: <13 Sec

Alarm: User-selectable upper and lower SpO2 limits

PR

Measurement Range: 25~250 bpm

Resolution: 1 bpm

Accuracy: ±1% or ±1 bpm, whichever is greater

Data update period: <13 Sec

Alarm: User-selectable upper and lower pulse rate limits

NIBP

Way of measurement: Automatic oscillometry

Range of measurement:

Adult: SYS: 30~270 mmHg; DIA: 10~220 mmHg; MEAN: 20~235 mmHg

Cuff pressure range: 0~280 mmHg (0¡«300mmHg at HYPER mode)

Resolution: 1 mmHg

Pressure Accuracy: ±2% or ±3 mmHg, whichever is greater

Static: ±5 mmHg average error

Clinical: 8 mmHg standard deviation

Unit: mmHg, kPa

Pulse rate range: 40 ~ 240 bpm

Inflation time for cuff: Less than 40 sec. (standard adult cuff)

Total cycle time: 20 to 45 seconds typical (dependent on heart rate and motion artifact)

Intervals for AUTO measurement: 1,2,3,4,5,10,15,20,30,45,60,90 minutes 2,4,8 hours

Overpressure Protection: Hardware and software double protections; Adult: 315±10 mmHg

Range of alarm:

SYS: 0~300 mmHg, continuously adjustable between upper and lower limit

DIA: 0~300 mmHg, continuously adjustable between upper and lower limit

MEAN: 0~300 mmHg, continuously adjustable between upper and lower limit

Alarm indication: Sound and light alarming

Measurement Mode: Adult: Manual, Auto and STAT

IBP(Option)

Measurement Range: -50 ~ +300 mmHg

Resolution: 1 mmHg

Unit: mmHg, kPa

Accuracy: ± 2mmHg or 2% of the reading, whichever is greater (exclusive of transducer)

Static: ± 4mmHg or 4% of the reading, whichever is greater (inclusion of transducer)

Dynamic: ± 4mmHg or 4% of the reading, whichever is greater

Sensitivity of transducer: 5uV/V/mmHg, 2%

Impedance of transducer: 300~3000 Ohm

Bandwidth: d.c. ~ 15Hz

Transducer sites: Arterial Pressure (ART), Pulmonary Artery Pressure (PA), Left Atrium Pressure    (LAP), Right Atrium Pressure (RAP), Central Venous Pressure (CVP)

Selection of measurement range:

ART: 0~200mmHg

PA: 0~300 mmHg

CVP: -10~20 mmHg

LAP: -50~300 mmHg

RAP: AUTO

ICP: AUTO

Alarm indication: Sound and light indication

EtCO2  (Sidestream£¬CPT) (Option)

Measure method: Infrared spectrum

Measure mode: Sidestream

Measurement Range: 0.0~13.1% (0~99.6 mmHg)

Resolution: 1 mmHg

Unit: %, mmHg, kPa

Accuracy: At <5 % CO2, ±3% (±2.0 mmHg); At ≥5 % CO2, < ±10 % of reading

Range of respiration rate measurement: 3~150 rpm

Calibration: Offset calibration: auto, manual; Gain calibration

Range of alarm: 0.0~13.1 % (0~99.6mmHg), continuously adjustable between upper limit and lower limit

Alarm indication: Sound and light indication

EtCO2  (Mainstream£¬IRMA) (Option)

Measure method: Infrared spectrum

Measure mode: Mainstream

Measurement Range: 0.0~13.1% (0~99.6 mmHg)

Resolution: 1 mmHg

Unit: %, mmHg, kPa

Accuracy: At <5 % CO2, ±3% (±2.0 mmHg); At ≥5 % CO2, < ±10 % of reading; Other range unspecified.

Rise time (10 l/min): ≤ 60 ms

Total system response time: < 2 seconds

Range of respiration rate measurement: 3~150 rpm

RR Accuracy: ±1 rpm

Range of alarm: 0.0~13.1 % (0~99.6mmHg), continuously adjustable between upper limit and lower limit

Alarm indication: Sound and light indication

Printer (Option)

Method: Thermal dot array

Paper width: 50 mm (1.97 in)

Paper Speed: 12.5/25/50 (mm/sec)

Traces: Maximum 3 tracks

Alarm

Level: Low, medium and high

Indication: Auditory and visual

Setup: Default and custom

Silence: All alarms can be silenced

Volume: 45~85 dB measured at 1 meter

Trend

Trend data and trend maps: Store & review 168 hours trend data and trend maps

Parameter option of Trend: HR, SpO2, NIBP, PR, Resp, CO2, Temp1, Temp2, AA, N2O, O2, IBP1, IBP2, ST.

Cycle intervals of trend storage: 1mim, 2min, 3min, 4min, 5min, 10min, 15min, 20min, 25min, 30min.

Reviewing

ECG waveform: Store & review 30 minutes one important lead’s ECG waveform

Alarm events: Store & review 1800 groups Alarm events reviewing

NIBP measurement: Store & review 1000 groups NIBP measurement

Arrhythmia: Store & review 128 groups arrhythmia data (8 seconds ECG waveforms)

Standard Accessories

5-lead ECG cable: 1pc

ECG disposable electrode: 10pcs

NIBP reusable adult cuff with air hose & connector: 1 set

Digital adult reusable SPO2 sensor: 1 pc

Temp reusable skin probe: 1 pc

Rechargeable sealed lead-acid battery 12V: 1 pc

Power line: 1pc

Optional Accessories

Nellcor SPO2 with accessories kit

2-IBP with accessories kit

2-Temp

EtCO2 (side stream) with accessories kit

EtCO2 (main stream) with accessories kit

12 lead ECG modular

Thermal recorder (including 1 roll paper)

3-lead ECG cable

NIBP reusable pediatric / neonatal cuff

Digital pediatric / neonatal reusable SPO2 sensor

Digital Adult soft clip SPO2 sensor

Temp reusable rectal probe

Trolley

Wall mount bracket

 

 

 