ProductIntroduce: Function and Features
l Three kinds of modes: Rate Mode, Time Mode, Body Weight Mode.
l Double CPU, making the process of injection safer and more reliable.
l Accurate and sensitive pressure sensor detecting occlusion pressure accurately.
l Injection time, dose, solution can be checked during the process of injection.
l Precision step motor. There is no pulsating wave even during low-rate injection.
l KVO rate can be selectable according to concrete requirements from 0.1ml/h to 5ml/h.
l Excellent injection operation. The accuracy will be ensured even at small-volume injection.
l Unique injection supervision system ensures the safe injection and reduces the nurse’s workload.
l Accept all standard syringes of 5ml, 10ml, 20ml, 30ml and 50ml. It will self-diagnose and display the syringe size and set parameter automatically in the form of menu.
l Alarm is given when there is malfunction or operation error, and the machine stops running automatically.
l Save the preset volume automatically when there is unpredictable switch off, ensuring the accuracy of injection volume.
Technical parameters of 500II Syringe pump
Applicable syringes
|
All brands of standard syringes: 5ml,10ml,20ml,30ml,50ml
|
|
Weight
|
<3.0kg
|
|
Accuracy
|
±2%
|
Dimension
|
380×190×180mm
|
|
Injection increment
|
0.1ml
|
Power supply
|
AC100~240V, 50/60Hz
|
|
Occlusion value
|
40kPa~160kPa
|
Fuse
|
T2AL250V~
|
|
Injection rate
|
5ml: 0.1 ml/h -100ml/h 30ml: 0.1 ml/h -600ml/h
10ml: 0.1 ml/h -200ml/h 50ml: 0.1 ml/h -1500ml/h
20ml: 0.1 ml/h -400ml/h
|
Maximum power consumption
|
25W, can run for 4h after being recharged
|
|
Battery
|
Rechargeable lithium polymer battery, 7.4V, 1600mAh
|
|
Accumulated injection volume
|
0.1ml~9999.9ml
|
Battery recharge
|
When the pump is connected to the AC power supply, turn on the power and the battery will automatically recharge (about 8~14 hours to recharge fully.)
|
|
Modes of operation
|
Selectable: Rate mode, Time mode, Body Weight mode
|
|
Time mode
|
Volume limit: 0.1~999.9ml Time: 1~2000 minutes
|
|
Electrical safety
|
Comply with the stipulation of IEC60601-1: 1996
|
|
Body weight mode
|
Drug limit:0.1~999.9mg, Solution limit:0.1~999.9ml, Weight: 01~300.0kg, Dose: 0.1~9999.9 mg/kg/h, ug/kg/min
|
|
Electromagnetic compatibility
|
Comply with the stipulation of IEC60601-1-2: 2006
|
|
Displayed information
|
Rate, volume limit, accumulated injection volume, syringe size, pressure value, battery capacity, unit of medical dosage, bed No., AC power indicator, battery charge indicator, drug name, bolus rate
|
Shell material
|
ABS plastic
|
|
Classification
|
II Class-BF
|
|
Alarm function
|
OVER, NEAR, Occlusion, Low battery, Syringe disengaged, No AC power supply, serious low battery
|
Operating conditions
|
Environment temperature 5°C ~40°C, air pressure 80kPa ~106kPa, relative humidity ≤80%
|
|
Storage conditions
|
Environment temperature -40°C~55°C, air pressure 50kPa ~106kPa, relative humidity ≤95%
|
|
KVO rate
|
0.1ml/h-5.0ml/h (selectable)
|
Applied standards
|
IEC60601-1: 2005
IEC60601-2-24: 1998
IEC60601-1-2: 2006
ISO780-1997
ISO15223: 2000
ISO7886-1: 1993
ISO / IEC: Guide No. 37《Consumer Goods Usage Instructions》
|
|
Bolus rate
|
5ml: 100ml/h
10ml: 200ml/h
20ml: 400ml/h
30ml: 400ml/h-600ml/h
50ml: 400ml/h-1500ml/h
|
|
|