ProductIntroduce:
KGW-5000D Ventilator
Ø CE marked
Ø For patients at different ages, neonatal, pediatric and adult.
Ø Optional DualPAP (Dual positive airway pressure),PRVC,NPPV(NIV)
Ø Flexible plug-in modules (optional): CO2, SpO2.
Ø Nebulizer (optional)
Ø 15 inch touch screen & big font display for easy review.
Ø Touch screen + navigation wheel for simple operation.
Ø Expiratory valve could be taken off for autocalvable disinfection to avoid cross-infection and reduce cost.
Reliability & Safety
Ø Close-loop control system provides airway compliance and leakage compensation, so as to realize accurate ventilation control.
Ø Key components are imported from word leading manufacturers to ensure high accuracy and stable performance.
Ø Patented proportional valve control technology.
Ø Multiple pressure and volume automatic protective system
n pressure releasing valve for gas supply
n 12.5kPa pressure releasing valve for airway
n pressure alarm setting
n expiratory safety valve
Ø Comprehensive alarm system
n monitoring and alarm for system failure: technology alarm
n monitoring and alarm for physiological parameters: physiological alarm
n three-level alarms for different risks.
n three-level alarms for different risks with different visual and aural signs.
Considerate Design
Ø 15 inch screen with big font for distance-review.
Ø With parameters setting/display and graphic display in the screen.
Ø Touch screen + navigation wheel; convenience & simple. “Choose-set-confirm” to realize function and avoid mis-operation.
Ø setting parameters display is subject to ventilation modes.
Ø System log could record 100 settings/alarms
Weight-VT presetting
Ø According to clinical research, weights have close relationship with tidal volume。 The ventilator could give presetting tidal volume through patients’ weights. The system could calculate reference value of tidal volume based on the change of weights.
Assistant functions
Ø 100% O2 2mins: offer 2 mins 100% O2 ventilation.
Ø Inspiration hold:keep inspiration hold for 30s.
Ø Expiration hold:keep expiration hold for 30s.
Ø Manual inspiration: offer inspiration once in expiration phase according to preset parameters
Ø Waveform forzening(optional) : Waveforms are frozen. Waveforms will be activated by another press.
Powerful Function
Ø Various ventilation mode
n A/C(VC)
n A/C(PC)
n SIMV
n SPONT
n DualPAP(optional)
n PRVC (optional)
n NPPV(NIV) (optional)
Ø Waveform
n P-T, F-T,V-T
n optional:SpO2-T,EtCO2-T
Ø Loop
n V-P,F-V,F-P (Optional)
n Optional: V-CO2
Ø Monitoring parameters
n (VTI/VTE);
n (MV/MVspn);
n fspon/f
n I:E;
n PEEP;
n Ppeak, Pplat, Pmean
n FiO2
n Resistance, compliance
n Optional :
- SpO2, Pulse rate
- InCO2/EtCO2);
Ø Powerful extended function: CO2 module(optional)
n Respironics CAPNOSTAT 5 mainstream CO2 module
n Display real-time monitoring and waveform in the user interface.
n Provide corresponding alarm setting.
Ø Powerful extended function :SpO2 module(optional)
n Display real-time monitoring and waveform in the user interface.
n Provide corresponding alarm setting.
Specification KGW- 5000D
|
Patients
|
Neonate (>5kg) 、pediatric and adult
|
Ventilation mode
|
VCV,PCV,SIMV+VCV+PSV,SIMV+PCV+PSV,SPONT,Standby. Optional: DualPAP/ PRVC/ NPPV(NIV)
|
Setting parameters
|
|
VT
|
20~2000 mL
|
f
|
1~100 bpm
|
Ti
|
0.1~10 s
|
Pressure trigger
|
-20~0 cmH2O
|
Flow trigger
|
0.5~20 L/min
|
Pressure control
|
5~70 cmH2O
|
Pressure support
|
0~70 cmH2O
|
High pressure
|
5~70 cmH2O
|
Low pressure
|
0~50 cmH2O
|
FiO2
|
21%~100%
|
E-PEEP
|
0~50 cmH2O
|
Monitoring parameters
|
VTI, VTE, MV, MVspon, f, fspon, I:E, Ppeak, Pmean, Pplat, Pmin, FiO2, C, R.
|
Waveform
|
P-T,F-T,V-T.
Optional: SpO2-T, EtCO2-T.
|
Loop
|
V-P.F-V,F-P Optional: V-EtCO2
|
Extended function
|
|
CO2 module
|
Optional: Respironics CAPNOSTAT 5 mainstream CO2 module.
|
Monitoring range
|
0~99 mmHg
|
Alarm range
|
High limit:1~99 mmHg,OFF
Low limit:OFF,0~98 mmHg
|
SPO2 module
|
optional
|
SPO2 range
|
0~100%
|
Pulse rate range
|
30~250 bpm
|
SPO2 alarm range
|
80%~100%
|
Alarm setting
|
Low tidal volume, high/low limit of minute ventilation, high/low limit of frequency, high/low limit of FiO2, high/low limit of airway pressure, high continuous airway pressure, apnea, O2 failure, air supply failure, mains failure, battery low capacity, and battery exhausted.
|
Alarm mute
|
< 120s
|
Physically
|
|
Screen
|
15 inch TFT touch screen,
|
Communication connector
|
VGA,RS232,RJ45,debugging interface
|
Dimension
|
710×915×665 mm3(H×W×D)
|
Net weight
|
45 Kg
|
Power
|
100 to 240 VAC,50/60 Hz,1A(Max.)
|
Lithium Battery
|
60 minutes
|
|