ProductName£º Anesthesia Machine KGW852-E
ProductIntroduce£º

Features

·                       More Accurate, Safer and More Convenient

·                       CE marked, meet EU clinical requirements

·                       ISO quality guarantee

·                       Suitable for adult and pediatric

·                       Pin-Index for N2O/O2 Cylinder

·                       Integrated high temperature sterilization and CO2 absorber system

·                       Newly-developed reliable gas system

 

Specifications

Physical and Environmental Specification

Demension: L560xW6725xH1288

Storage temperature: -22°c~+55°c

Working temperature: +10°c~+40°c

Storage humidity: ≤93°c

 

Electronic Specification

Power supply: AC100~240V±10%, 50/60Hz±1%

Power consumption: ≤50VA

 

Pneumatic Specification

1. Gas supply: O2/N2O, 0.28MPa~0.6MPa

2. Flowmeters:

O2: 0~1L/min, 1~10L/min

N2O: 0~1L/min, 1~10L/min

Two-tube flowmeter, 0~10L/min (With interlock protection devices ensuring the oxygen concerntration > 21%

3. O2 flush: 25~75L/min

4. Working mode: Closed, Semi-closed, Semi-opened

5. APL valve: ≤6KPa

6. O2 supply trouble alarm: O2 pressure lower than 0.14MPa

7. N2O cut off: O2 pressure lower than 0.1MPa

8. Supplementary O2 supply

9. O2/N2O Pin-index

 

Vaporizer

1. Support 3 vaporizers (Selectatec compatible)

2. Agent type: Sevoflurane, Halothane, Isoflurane available

3. Flow range: 0.2~15L/min

4. Concentration: 0~5% (Sevoflurane 0~8%)

5. Working temerature: 15~35°c

 

Ventilator specification

1. Patient type: pediatric and adult

2. Ventilation mode: IPPV, MANUAL

3. Driven mode: Pneumatically driven electronically controled

4. Tidal volume: 50ml~1500ml

5. Ventilation frequency: 0~60bpm

6. I:E rate: 1:1~1:4

7. High pressure: 1~8KPa

8. Low pressure: 0~2KPa

9. Safety valve pressure limit: ≤10KPa

 

Monitoring

Display: LEM display

Pressure: -2~10KPa

Tidal volume: 0~2000ml

Respiratory frequency: 0~120bpm

 

Alarm

Upper airway pressure limit

Upper airway pressure limit

 

 

ADD: C-1123, JIAHUI GLOBAL PLAZA, 548, BEIYUAN ROAD, TIANQIAO DISTRICT , JINAN CITY, SHANDONG PROVINCE ,CHINA TEL: 0086-531-89006948 FAX:0086-531-89006648